$979.00
Kit of 96 tests. Find various details on this Hyphen BioMed product, here. Available online.
PRODUCT DESCRIPTION
For Research Use Only. Not for Use in Diagnostic Procedures. ELISA method for the measurement of IgM isotype auto antibodies targeted to protein S. Assay designed with highly purified human protein S, obtained with non-denaturing methods, for autoantibody immunocapture. These are then revealed with a goat antibody specific for IgM, µ fragments, and labeled with peroxidase. This is an ON-DEMAND item which requires minimum order quantity and extended lead time. Please Contact Us for a quote.
Kit of 96 tests. Find various details on this Hyphen BioMed product, here. Available online.
PRODUCT CHARACTERISTICS
Total Assay Time: 1 hr 15 min
Detection Threshold: ≤ 5 AU*
Normal Range: ≤ 10 AU*
Intra-Assay CV: 3 to 6%
Inter-Assay CV: 4 to 8%
*AU: Arbitrary Unit (Mean + 2SD = 10AU)
PRODUCT COMPONENTS
Micro ELISA Plate (12 strips of 8 wells)
2x Sample Diluent
3x Anti-Protein S, IgM Calibrator
3x Negative Control
3x Anti-IgM (µ)-HRP IC
1x Conjugate Diluent
1x Wash Solution
1x TMB
1 x 0.45M Sulfuric Acid
PRODUCT APPLICATION
For the measurement of IgM isotype auto antibodies targeted to Protein S in research applications.
Please Note: Results obtained should be for research purposes only and not used for patient diagnosis or treatment.
MSDS Documents
IFU Documents